Build Your Online Product Catalogs?
Product Name: |
3051 Single Flange Capacitive Differential Pressure Transmitter
|
Supply Ability: |
|
Related proudcts |
high precision, high stability, |
Specifications |
0.20~25 Second£»5 ~ 98% Rh£»-40 ~ 104 ¡ãC |
Price Term: |
|
Port of loading: |
|
Minimum Order |
|
Unit Price: |
|
|
The&©|160;capacitive differential pressure transmitter can measuring liquids' level and density of kinds of container accurately. Transmitter is mounted to the container with pipe flange. Be propitious to measuring medium of high temperature,high viscosity and easy to subside or strong corrosive.Diaphragm subassembly have plane and plug-in types.flange size: 3inch and 4inch; pressure grade: 50Ib and 300Ib. The membrane can select 316 stainless steel, Hastelloy or tantalum according to measure medium.&©|160; &©|160; Product Overviews &©|160; Range Range code Range Measuring range Min. Max. 4 0.374KPa 37.4KPa -37.4~37.4KPa 5 1.868KPa 186.8KPa -186.8~186.8KPa 6 6.9KPa 690KPa -690~690KPa &©|160; Technical Data&©|160; Output Analog output: two -wire 4-20mADC Digital output: two -wire 4-20mADC and superimposing variable digital signal accord with HART Power supply supply voltage 12.5-45VDC Limit load Max load resistor Rmax in loop decided by the supply voltage, see the below drawing. HART PROTOCOL require the load resistor not less than 250¦¸,not more than 600¦¸ Communication distance Max. 1.5Km, multi-address communication can connect 15 smart transmitters Max. Display 4 digital display,5 digit LCD display, pointer type. Explosion-proof ExiaIICT5;explosion suppression type Zero offset Can positive transfer or negative transfer, but can not overstep the utmost value Temperature ambient temperature -40-85oC(When choose LCD : -20-70oC) Medium temperature -40~104oC Static pressure and single side overpressur 3.45KPa(absolute pressure)~31.2***(gauge pressure) Relative humidity 5~98%RH Run-up time less than 5 sec. Capability change Less than 0.16cm3 Damp adjust 0.20~25 second Malfunction alarming If occur malfunction, automatism diagnose function will output 3.9 or 21.0mA Configuration protection To avoid the datas are modified random, can utilize software or protect switch lock the record data |
Company: |
Xi¡¯an Yun Yi Instrument Co., Ltd
|
Contact: |
Ms. Daisy yang |
Address: |
Room 1203B, Inland Port Mansion, No.9 Gangwu Road, Xi'an International Trade & Logistics Park |
Postcode: |
|
Tel: |
029-86339633 |
Fax: |
029 88637182 |
E-mail: |
|
|
|
|